Literatur- und Veröffentlichungsliste
Veröffentlichungen der Arbeitsgruppe zum Thema
Vorträge
- R. Rawer:
Vergleich der Abbildungsqualität hydrophober Acryl-Intraokularlinsen mit und ohne Blaulichtfilter vor und nach der Injektion durch eine Kartusche
Symposium: Hydrophobe Acryl-Intraokularlinsen mit und ohne Blaulichtfilter, Internationaler Erfahrungsaustausch über eine neue Generation von Intraokularlinsen, Wien, Oktober 2004
- R. Rawer, W. Stork, C. Lingenfelder, C.W. Spraul:
Analysis of the optical imaging quality of foldable Intra Ocular Lenses (IOL) before and after injection through a cartridge by comparative measurement of the Point Spread Function (PSF) according to ISO Standard,
XXII Congress of the European Society of Cataract and Refractive Surgeons, Paris, 2004
- R. Rawer, W. Stork, C. Lingenfelder, C.W. Spraul:
Comparative measurement of the optical imaging quality of foldable Intra Ocular Lenses (IOL) by analysis of the Point Spread Function (PSF) according to ISO Standard before and after injection through a cartridge,
102. Jahrestagung der Deutsche Ophthalmologische Gesellschaft (DOG), Berlin, 2004
Buchbeiträge
- [Rawer05b] R. Rawer:
Vergleich der Abbildungsqualität hydrophober Acryl-Intraokularlinsen mit und ohne Blaulichtfilter vor und nach der Injektion durch eine Kartusche
Symposium: Hydrophobe Acryl-Intraokularlinsen mit und ohne Blaulichtfilter, Herausgeber S. Binder, R. Welt, R.D. Gerste, ad manum medici Verlag für Medizin und Naturwissenschaften, Germering, ISBN 3-928027-25-5, 2005, s.15-24
Zeitschriftenbeiträge
- [Rawer05c] R. Rawer, W. Stork, C. Lingenfelder, C.W. Spraul:
Comparative measurements of the imaging quality of foldable Intraocular Lenses by analysis of the point Spread Function (PSF) according to ISO requirements before and after injection through a cartridge
Graefe's Archive for Clinical and Experimental Ophthalmology, submitted August 2004
- [Spraul05] C.W. Spraul, R. Rawer, W. Stork, P. Walther, C. Lingenfelder, G.K. Lang:
Spielt die Orientierung einer IOL im Auge eine Rolle?
Klinische Monatsblätter für Augenheilkunde, submitted January 2005
- [Rawer05a] R. Rawer, W. Stork:
Imaging Quality of Intraocular Lenses,
ESCRS, Journal of Cataract & Refractive Surgery, 31/8:1618-163, August 2005
- [Eisenmann93] D. Eisenmann, V. Hessemer, B. Manzke, W. Stork, K.W. Jacobi:
Modulationsübertragungsfunktion und Kontrast-empfindlichkeit refraktiver Mehrzonenmultifokallinsen
Ophthalmologe, 90:343-347, 1993
Weitere Literaturverweise
[Akutsu93] | Akutsu, H., Legge, G.E., Luebker, A., Lindstrom, R.L., Zabel, R.W., Kirby, V.M.: Multifocal Intraocular Lenses and Glare Optometry and Vision Science, AAO, 1993, 70/6:478-95 |
[Brennan97] | Liou, H-L, Brennan: A. Anatomically accurate, finite eye model for optical modeling J. Opt. Soc. of America. A., 1997, A14/8:1684-95 |
[Brennan04] | Liou, H-L, Brennan: Eye model for the prediction of contrast vision in patients with new intraocular lens designs Optics Letters, OSA, 2004, 29/7:733-35 |
[Charman96] | Charman, W.N.: Handbook of Optics Volume I. McGraw-Hill, 1996, 24.17-18 |
[Hecht98] | Hecht, E.: Optik Oldenbourg Verlag, 1998, 6.3 |
[Holladay87] | Holladay, J.T., King, A.C., Koester, C.J.: Intraocular lens resolution in air and water J. Cataract Refract. Surg., 1987, 13:511-517 |
[Holladay88] | Holladay, J.T., King, A.C., Koester, C.J.: Silicone intraocular lens resolution in air and water J. Cataract Refract. Surg., 1988, 14:657-659 |
[Holladay93] | Holladay, J.T. et.al: Intraocular lens performance in air, in water and in situ: a computer study J. Cataract Refract. Surg., 1993 , 19:499-504 |
[Holladay02] | Holladay, J.T. et.al: A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes J. Cataract Refract. Surg., 2002, 18:683-691 |
[ISO9334] | EN/ISO 9334: Optical Instrument – Optical Transfer Function – Definitions and Mathematical Relationsships 2002 |
[ISO9335] | EN/ISO 9335: Optical Instrument – Optical Transfer Function – Principles and Procedures of Measurement 2002 |
[ISO11979] | EN/ISO 11979-2: Ophthalmic implants – Intraocular lenses – Part 2: Optical properties and thest methods 1999 |
[Knorz92] | Knorz, M.C. et.al.: Comparison of modulation transfer function and through focus response with monofocal and bifocal IOLs Ger. J. Ophthalm., 1992, 1:45-53 |
[Norrby98] | Norrby, N.E., Patel, A.S., Silberman,D.M., et.al.: Determining the imaging quality of intraocular lenses J. Catarcat Refract. Surg., 1998, 24:703-14 |
[Oshika99] | Oshika, T., Klyce, S.D., Applegate, R.A., Howland, H.C.: Changes in Corneal Wavefront Aberrations with Aging Inv. Ophthalmo. & Vis. Science, 40/7:1351-55, 1999 |
[Oyster99] | Oyster, C.W.: The Human Eye – Structure and Function, Sinauer Associates ISBN 0-87893-645-9, 1999 |
[Piers04] | Pier, A., Norrby, N.E.S.: Eye models for the prediction of contrast vision in patients with new intraocular lens designs Optics Letters, OSA, 2004, 29/7:733-35 |
[Schwieger00] | Schwiegerling, J.: Theoretical Limits to Visual Performance Survey of Ophthalmology, 2000, 45/2:139-46 |
[Tognetto04] | Tognetto, D.T. et.al.: Analysis of the Optical Quality of Intraocular Lenses Inv. Ophthalmol. & Vis. Sc. (IOVS), 2004, 45/8:2682-90 |